APPLICATION EXAMPLES


Input the sensor detection signal into AcH and BcH of AMH-148 and inspect the lead cut length using the operation function (A -B). The operation result is compared and decided at a high-speed sampling rate of 1000 times/second. Furthermore, it is possible to find the maximum and minimum of the calculated value using the peak-hold and valley-hold functions.


The pattern selection function can memorize 8 kinds of upper upper-limit, upper-limit, lower-limit, and lower lower-limit set values and hysteresis values, as well as 8 kinds of scaling values. The tolerance range can be instantly switched with the front switch This is very useful for flexible lines that contain multiple materials.






For example, digital panel meter A6000 for AC measurement has standardized range for CT connection. This meter inputs 5A on secondry side of CT to enable scaling of any current value on the primary side.






The analog signals from the laser displacement sensors installed at two locations of a printed circuit board are input to AcH and BcH of AMH-148 and A – B is calculated to detect product defects












Gear B revs can be found from gear A revs using the prescaling function.


A lineup of items is provided so that a size that matches the installation space can be selected according to the purpose


WPM-1 has a power supply 24VDC(50mA) or 12VDC(100mA) for sensors, a scaling function, and an analog comparator, enabling low-cost inspection system.


2) Input 2ch, Display Ach & Bch value in 1 display.
3) WPMZ-1 can Calculate difference of 2ch input (Ach – Bch).
If calculation result is below or over setpoints (4 setpoints setting available) when one of RTD broken etc., then Relay signal will output to detect.


![]() | Example of Calculation method |












Point
1) Using IoT gateway together with RS-485 (Modbus RTU) devices, able to monitor sensor signals, demand / power, air conditioning control at remote locations.2) Power measuring Modbus I/O Module WMB-DI16 can input 16ch pulse from power meter’s pulse output.
3) Air conditioning control Modbus I/O Module WMB-DIO8R can output x8ch relay.
4) Sensor signal monitoring LCD Graphical panel meter WPMZ has 1/2 ch input with RS-485 Modbus RTU.


Point
1) Measured data by WMB & WPMZ, and convert RS-485 Modbus RTU to Ethernet Modbus TCP by Modbus TCP/RTU converter. Then you can monitor data at PC on Ethernet.2) Our WMB & WPMZ are Modbus RTU slave units.