ADA Series
Product Name | Output Wattage | Output Voltage・Current |
---|---|---|
ADA600F-24 | 336W (Peak: 600W) ACIN 100V Convection Cooling 504W (Peak: 600W) ACIN 100V Forced Air Cooling 360W (Peak: 744W) ACIN 200V Convection Cooling 600W (Peak: 744W) ACIN 200V Forced Air Cooling |
24V 14A (Peak :25A) ACIN 100V Convection Cooling 24V 21A (Peak :25A) ACIN 100V Forced Air Cooling 24V 15A (Peak :31A) ACIN 200V Convection Cooling 24V 25A (Peak :31A) ACIN 200V Forced Air Cooling |
ADA600F-30 | 330W (Peak: 600W) ACIN 100V Convection Cooling 495W (Peak: 600W) ACIN 100V Forced Air Cooling 360W (Peak: 735W) ACIN 200V Convection Cooling 600W (Peak: 735W) ACIN 200V Forced Air Cooling |
30V 11A (Peak :20A) ACIN 100V Convection Cooling 30V 16.5A (Peak :20A) ACIN 100V Forced Air Cooling 30V 12A (Peak :24.5A) ACIN 200V Convection Cooling 30V 20A (Peak :24.5A) ACIN 200V Forced Air Cooling |
ADA600F-36 | 324W (Peak: 594W) ACIN 100V Convection Cooling 504W (Peak: 594W) ACIN 100V Forced Air Cooling 360W (Peak: 738W) ACIN 200V Convection Cooling 594W (Peak: 738W) ACIN 200V Forced Air Cooling |
36V 9A (Peak :16.5A) ACIN 100V Convection Cooling 36V 14A (Peak :16.5A) ACIN 100V Forced Air Cooling 36V 10A (Peak :20.5A) ACIN 200V Convection Cooling 36V 16.5A (Peak :20.5A) ACIN 200V Forced Air Cooling |
ADA600F-48 | 312W (Peak: 600W) ACIN 100V Convection Cooling 504W (Peak: 600W) ACIN 100V Forced Air Cooling 336W (Peak: 744W) ACIN 200V Convection Cooling 600W (Peak: 744W) ACIN 200V Forced Air Cooling |
48V 6.5A (Peak :12.5A) ACIN 100V Convection Cooling 48V 10.5A (Peak :12.5A) ACIN 100V Forced Air Cooling 48V 7A (Peak :15.5A) ACIN 200V Convection Cooling 48V 12.5A (Peak :15.5A) ACIN 200V Forced Air Cooling |
Product Name | Output Wattage | Output Voltage・Current |
---|---|---|
ADA750F-24 | 408W (Peak: 1008W) ACIN 100V Convection Cooling 600W (Peak: 1008W) ACIN 100V Forced Air Cooling 456W (Peak: 1512W) ACIN 200V Convection Cooling 756W (Peak: 1512W) ACIN 200V Forced Air Cooling |
24V 17A (Peak :42A) ACIN 100V Convection Cooling 24V 25A (Peak :42A) ACIN 100V Forced Air Cooling 24V 19A (Peak :63A) ACIN 200V Convection Cooling 24V 31.5A (Peak :63A) ACIN 200V Forced Air Cooling |
ADA750F-30 | 405W (Peak: 1005W) ACIN 100V Convection Cooling 600W (Peak: 1005W) ACIN 100V Forced Air Cooling 450W (Peak: 1500W) ACIN 200V Convection Cooling 735W (Peak: 1500W) ACIN 200V Forced Air Cooling |
30V 13.5A (Peak :33.5A) ACIN 100V Convection Cooling 30V 20A (Peak :33.5AACIN 100V Forced Air Cooling 30V 15A (Peak :50A) ACIN 200V Convection Cooling 30V 24.5A (Peak :50A) ACIN 200V Forced Air Cooling |
ADA750F-36 | 396W (Peak: 1008W) ACIN 100V Convection Cooling 594W (Peak: 1008W) ACIN 100V Forced Air Cooling 450W (Peak: 1512W) ACIN 200V Convection Cooling 738W (Peak: 1512W) ACIN 200V Forced Air Cooling |
36V 11A (Peak :28A) ACIN 100V Convection Cooling 36V 16.5A (Peak :28A) ACIN 100V Forced Air Cooling 36V 12.5A (Peak :42A) ACIN 200V Convection Cooling 36V 20.5A (Peak :42A) ACIN 200V Forced Air Cooling |
ADA750F-48 | 384W (Peak: 1008W) ACIN 100V Convection Cooling 600W (Peak: 1008W) ACIN 100V Forced Air Cooling 432W (Peak: 1512W) ACIN 200V Convection Cooling 744W (Peak: 1512W) ACIN 200V Forced Air Cooling |
48V 8A (Peak :21A) ACIN 100V Convection Cooling 48V 12.5A (Peak :21A) ACIN 100V Forced Air Cooling 48V 9A (Peak :31.5A) ACIN 200V Convection Cooling 48V 15.5A (Peak :31.5A) ACIN 200V Forced Air Cooling |
Product Name | Output Wattage | Output Voltage・Current |
---|---|---|
ADA1000F-24 | 504W (Peak: 1512W) ACIN 100V Convection Cooling 792W (Peak: 1512W) ACIN 100V Forced Air Cooling 600W (Peak: 1992W) ACIN 200V Convection Cooling 1008W (Peak: 1992W) ACIN 200V Forced Air Cooling |
24V 21A (Peak :63A) ACIN 100V Convection Cooling 24V 33A (Peak :63A) ACIN 100V Forced Air Cooling 24V 25A (Peak :83A) ACIN 200V Convection Cooling 24V 42A (Peak :83A) ACIN 200V Forced Air Cooling |
ADA1000F-30 | 495W (Peak: 1500W) ACIN 100V Convection Cooling 780W (Peak: 1500W) ACIN 100V Forced Air Cooling 600W (Peak: 1980W) ACIN 200V Convection Cooling 1005W (Peak: 1980W) ACIN 200V Forced Air Cooling |
30V 16.5A (Peak :50A) ACIN 100V Convection Cooling 30V 26A (Peak :50A) ACIN 100V Forced Air Cooling 30V 20A (Peak :66A) ACIN 200V Convection Cooling 30V 33.5A (Peak :66A) ACIN 200V Forced Air Cooling |
ADA1000F-36 | 504W (Peak: 1512W) ACIN 100V Convection Cooling 792W (Peak: 1512W) ACIN 100 V Forced Air Cooling 594W (Peak: 1980W) ACIN 200V Convection Cooling 1008W (Peak: 1980W) ACIN 200V Forced Air Cooling |
36V 14A (Peak :42A) ACIN 100V Convection Cooling 36V 22A (Peak :42A) ACIN 100V Forced Air Cooling 36V 16.5A (Peak :55A) ACIN 200V Convection Cooling 36V 28A (Peak :55A) ACIN 200V Forced Air Cooling |
ADA1000F-48 | 504W (Peak: 1512W) ACIN 100V Convection Cooling 792W (Peak: 1512W) ACIN 100V Forced Air Cooling 552W (Peak: 1992W) ACIN 200V Convection Cooling 1008W (Peak: 1992W) ACIN 200V Forced Air Cooling |
48V 10.5A (Peak :31.5A) ACIN 100V Convection Cooling 48V 16.5A (Peak :31.5A) ACIN 100V Forced Air Cooling 48V 11.5A (Peak :41.5A) ACIN 200V Convection Cooling 48V 21A (Peak :41.5A) ACIN 200V Forced Air Cooling |